What is PROFIBUS OLM?

PROFIBUS OLM is designed for use in optical PROFIBUS fieldbus networks. They allow conversion between electrical PROFIBUS (RS-485) to optical interface and vice versa.

The modules can be integrated in existing PROFIBUS fieldbus networks with known parameters

Advantages of optical transmission technology Complete PROFIBUS fieldbus networks can also be set up with modules in linear (bus), star or ring topology as well as any module connection combination of these topologies.

To increase the reliability of the fieldbus network in case of failure, redundant rings are supported.

PROFIBUS OLM

Optical range

The power channel is designed as a 9-pin D-sub socket. An RS-485 bus segment complying with the PROFIBUS EN 50170 /2/ standard can be connected to this channel.

The fiber optic cables are connected via BFOC1 /2.5 connector

Six multicolored LEDs indicate the current mode and any interruptions as well as the scale level on the optical interfaces.

PROFIBUS OLM

Network Topologies

The following network topologies can be deployed with PROFIBUS OLM:

  • Point-to-point connection
  • Bus topology (linear)
  • Star topology
  • Redundant optical ring

Linear (bus) Topology

PROFIBUS OLM

In a linear or bus structure, the single PROFIBUS OLMs are connected by two-fiber cables.
At the beginning and at the end of a line, modules with one optical channel are adequate, in-between modules with two optical channels are necessary.

Star Topology

PROFIBUS OLM

Several modules are grouped together to form an active PROFIBUS star coupler. Further modules are connected to this via two-core fiber-optic cables. The modules of the star coupler are interconnected via the electrical channel (electrical star segment). All OLM types for different fiber-optic cables (plastic, PCF, glass) can be combined via the electrical star segment.

Ring Topology

RING 1

This network topology is a special form of the bus topology. “Closing” the optical bus achieves high operational reliability in the network. A redundant optical ring can only be implemented using modules with two optical channels.

Redundant Optical Ring with two OLMs

PROFIBUS OLM

Setting up a redundant optical ring with two PROFIBUS OLMs can be seen as special case of the redundant optical ring and can be implemented with the
following two configurations.

Example of linear topology

PROFIBUS OLM

Equipment includes:

  • PLC S7-1200 CPU1212
  • Module Profibus master CP1243-5
  • Profibus OLM
  • ET200SP IM155-6DP HF
z5380156715943 05c99db692fb0dd182084c1051f77b63
z5380156713267 1cb41f5e335de6cda133567ac8aa273a
z5380156701748 4b56ca1180e9c36b47079696c3a5c3d0

Result

The devices are connected to each other via Profibus OLM. Helps extend distance and control more Note than you first

PROFIBUS OLM

Youtue

Cách tạo Connection definition point EPLAN HOANLK REST API PLC S7-1200 REST API

Manual

Share this…
  • Facebook
  • Twitter
  • Linkedin
  • Whatsapp
  • Pinterest
Tags: ProfibusProfibusProfibus OLMTIA PORTAL
hoanlk

hoanlk

Related Posts

SIEMENS Sim EKB Install TIA PORTAL V20
SIEMENS

SIEMENS Sim EKB Install TIA PORTAL V20

22/03/2025

SIEMENS Sim EKB Install TIA PORTAL V20 Below is the EKB application for Tia Portal V20 Link Tia Portal V20...

Get TagPrefix WINCC PRO V13-V19
SIEMENS

Get TagPrefix WINCC PRO V13-V19

22/03/2025

GetServerTagPrefix Description TagPrefix In order for a WinCC client in a distributed system to access tags of the associated server,...

Summary of errors in SIEMENS WINCC V7
SIEMENS

Summary of errors in SIEMENS WINCC V7

25/08/2024

I. Server not available, Cannot connect to server 1: Check whether SQL status is running or not in SQLServermanager 2:Check...

Hướng dẫn sửa lỗi SwacLogin error wincc unified
SIEMENS

How to do fix SwacLogin Error WinCC Unified V16-V18

08/09/2023

Swaclogin error message is displayed when an identity supplier cannot be accessed. Communication between WinCC's unified equipment is exclusively encrypted...

Kết Nối Ngành Tự Động Hóa Với HTTP REST API: Tiềm Năng Và Ước Mơ Của Tương Lai Công Nghệ
IOT

Connecting Automation Industry With HTTP REST API: Potential And Dream Of The Future Of Technology

15/08/2023

Nowadays, automation is becoming an integral part of every sphere of life and industry. From manufacturing, to resource management, to...

Profinet Siemens:Technology solutions for industrial automation – 1990
SIEMENS

Profinet Siemens:Technology solutions for industrial automation – 1990

12/08/2023

Profinet Siemens is one of the leading industry communication standards developed by Siemens, one of the world's largest and most...

Next Post
Kết nối OPC DA C# và KepwareV6

Connect OPC DA C# and KepwareV6

Summary of errors in SIEMENS WINCC V7

Summary of errors in SIEMENS WINCC V7

EPLAN Electric P8 API: Quick tips for creating design drawings

TIP EPLAN: How to Break Point Eplan P8

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

© 2023 HOANLK - Premium theme by HOANLK.

No Result
View All Result

© 2023 HOANLK - Premium theme by HOANLK.

Welcome Back!

Login to your account below

Forgotten Password? Sign Up

Create New Account!

Fill the forms below to register

All fields are required. Log In

Retrieve your password

Please enter your username or email address to reset your password.

Log In